Verify a commercial building by address
Match an address to the intended building and parcel before using footprint area, height, year built or assessment data in underwriting and lending.
Use Geocode to resolve the address, Fetch for footprint attributes at the confirmed coordinate, and Enrich for assessor fields on the containing parcel. Keep building, parcel and address identifiers together. On a campus, several buildings can share the same mailing address or tax lot, so a successful parcel lookup can leave the intended building unresolved.
Resolve the street address and confirm the building
Start with the submitted address, building name or unit, and any building identifier in the report. Use the returned normalized_address, accuracy_type, match_type, and source to check where the address was placed. A precise municipal address point may still represent a campus entrance or another structure on the same property.
Set INVARIANT_API_KEY to your API key. This request uses a public building address at the Brooklyn Navy Yard.
curl --fail-with-body --max-time 30 -sS 'https://api.invariant-ai.com/v1/geocode' \
-H "X-API-Key: $INVARIANT_API_KEY" \
-H 'Content-Type: application/json' \
--data '{"address":"141 Flushing Avenue, Brooklyn, NY"}'
Use a city footprint, property plan or survey to check the intended structure. NYC distinguishes the building identification number (BIN) for a building from the borough-block-lot (BBL) identifier for the tax lot. Use the jurisdiction’s own identifiers where available and keep the source namespace with them.
Get footprint attributes for the confirmed location
The coordinate below comes from the published city address point for 141 Flushing Avenue. The reference check confirmed that it falls inside the city polygon for Building 77. Replace the coordinate with the one you verified for your property.
curl --fail-with-body --max-time 75 -sS 'https://api.invariant-ai.com/v1/fetch' \
-H "X-API-Key: $INVARIANT_API_KEY" \
-H 'Content-Type: application/json' \
--data '{
"lat": 40.698574,
"lng": -73.971151,
"fields": [
"primary_building_footprint_sqm", "primary_building_height_m",
"primary_building_num_floors", "primary_building_overture_class",
"parcel_apn", "parcel_match_type"
]
}'
| Field | Check before using it |
|---|---|
primary_building_footprint_sqm |
Geodesic area of the selected Overture footprint in square metres. For the outline itself, use the source building geometry. |
primary_building_height_m and primary_building_num_floors |
Optional height and floor-count attributes of the selected building. Keep an unpublished attribute missing. |
primary_building_overture_class |
Overture’s mapped building class. Confirm tenant operations and occupancy separately before using them in an insurance submission. |
parcel_apn and parcel_match_type |
The parcel number and whether it contains the point or is a nearby candidate. Preserve the identifier as text. |
Check the Overture building ID and match description in each successful field’s notes. Fetch selects a containing building if one exists, otherwise the nearest within 100 m. Treat a nearby match as a candidate and compare it with the named structure. Overlaps and distance ties can produce a failed field. For a non-retryable match conflict, correct the coordinate or resolve the ambiguity with the source geometry. See field statuses and provenance.
Load the assessor record for the containing parcel
curl --fail-with-body --max-time 75 -sS 'https://api.invariant-ai.com/v1/enrich' \
-H "X-API-Key: $INVARIANT_API_KEY" \
-H 'Content-Type: application/json' \
--data '{
"lat": 40.698574,
"lng": -73.971151,
"fields": [
"parcelnumb", "structno", "yearbuilt", "year_built_effective_date",
"numstories", "area_building", "area_building_definition"
]
}'
Require a containing parcel_match before using assessor fields. A no_match result can show nearby parcels to investigate. Read field_omissions when a requested assessor field is unavailable.
| Assessor fields | What they describe |
|---|---|
parcelnumb, structno |
The published parcel number and the recorded structure count on the lot. More than one structure calls for a building-level record before assigning age or floor area to the submission. |
yearbuilt, year_built_effective_date, numstories |
The recorded year and stories of the main structure, plus the assessor’s effective construction year when supplied. A renovation can change the effective year. |
area_building, area_building_definition |
The assessor’s total building area on the parcel in square feet and the county’s measurement basis, such as gross or finished area. A footprint measures ground coverage. Compare equivalent area definitions and units. |
See the parcel field definitions for the exact scope of each field. Record the building ID, parcel ID, match type, measurement basis, date and source for each value you carry into a property record.
Run two campus address checks
The results below were reproduced on November 24, 2026, using NYC GeoSearch and NYC’s published building footprints. They are independent reference checks for the workflow. The Earth requests use the same example coordinate so you can review the returned Overture and parcel records with your key.
| Submitted building | City address and footprint evidence | Review result |
|---|---|---|
| Navy Yard Building 77, 141 Flushing Avenue | The address point is inside the city footprint labeled 77, BIN 3335143. |
The point and named city footprint agree. |
| Navy Yard Building 92, 63 Flushing Avenue | The address point falls inside the footprint labeled 280, BIN 3335129. The city footprint labeled 92 is BIN 3335175. Both use tax lot 3020230001. |
Hold the building match and confirm the intended structure using the operator’s building number and site plan. |
At Brooklyn Army Terminal, the city footprint record for BIN 3257059 reports 14 feet and construction year 2022. The operator’s Building A specification reports 89 feet and 1918 construction. Keep both records and mark the intended footprint unresolved until the geometry is reconciled. Download the exact city queries and Earth request bodies or open the Navy Yard source geometries.
After confirming the structure, check FEMA flood exposure or look up wildfire evidence. For a lender reviewing a multi-building property, match the legal description and collateral schedule to the lots and structures included in the transaction. Commercial property underwriting case and source records.